Air conditioner DAIKIN COMFORT FTX35JV + RX35JV
FEATURES
• Energy saving during standby mode: reduces current consumption by about 80% when operating In standby. If no people are detected for more than 20 minutes, the system will automatically switch to the current-saving mode.
• Energy efficient units: up to class A energy labels.
• ECONO mode decreases power consumption so that other appliances that need large power consumption can be used.
• Whisper quiet operation: down to 23dBA sound pressure level.
• Comfort function mode activates the programmed temperature levels intended for a home occupied during the day; default setpoints are 21°C in heating mode and 24°C in cooling mode and can be changed by the user.
• Night set mode saves energy by preventing overcooling or overheating during night time.
• Comfort mode guarantees draught free operation by preventing that warm or cold air is directly blown on to the body.
• Powerful mode can be selected for rapid heating or cooling; after the powerful mode is turned off, the unit returns to the preset mode.
• Whisper quiet operation: down to 22dBA sound pressure level.
• Indoor unit silent operation: SILENT button on the remote control lowers the operation sound of the indoor unit by 3dBA.
• Titanium apatite photocatalytic air purification filter removes airborne microscopic particles, powerfully decomposes odours and helps to prevent the propagation of bacteria, viruses, microbes to ensure a steady supply of clean air.
• Vertical auto swing moves the discharge flaps up and down for efficient air and temperature distribution throughout the room.
• Outdoor units for pair application.
• Outdoor units are fitted with a swing compressor, renowned for its low noise and high energy efficiency.
• Daikin outdoor units are neat, sturdy and can easily be mounted on a roof or terrace or simply placed against an outside wall.
TECHNICAL DATA
|
| INDOOR UNIT | FTX35JV |
| Casing colour | Alb / White |
| Dimensions (height x width x depth) | 283 x 770 x 198 mm |
| Weight | 7 Kg |
| Cooling capacity (kW) min. / nom. / max. | 1,3 / 3,3 / 3,8 |
| Cooling capacity (BTU/h) min. / nom. / max. | 4.400 / 11.000 / 13000 |
| Heating capacity (kW) min. / nom. / max. | 1,3 / 3,5 / 4,8 |
| Heating capacity (BTU/h) min. / nom. / max. | 4.400 / 11.900 / 16.400 |
| Power input nominal - Cooling (kW) | 980 W |
| Power input nominal - Heating (kW) | 930 W |
| Energy Efficiency Ratio (EER) | 3,37 |
| Coefficient of Performance (COP) | 3,76 |
| Energy label- Cooling | A |
| Energy label- Heating | A |
| Annual energy consumption (kWh) | 490 kWh |
| Air flow rate - Cooling |
• maxim: 9,3 mł/min;
• nominal: 7,7 mł/min;
• minim: 6,1 mł/min;
• silent: 4,8 mł/min.
|
| Air flow rate - Heating |
• maxim: 10,1 mł/min;
• nominal: 8,4 mł/min;
• minim: 6,7 mł/min;
• silent: 5,7 mł/min.
|
| Sound pressure level - Cooling |
• maxim: 41 dBA;
• nominal: 34 dBA;
• minim: 27 dBA;
• silent: 23 dBA.
|
| Sound pressure level - Heating |
• maxim: 41 dBA;
• nominal: 35 dBA;
• minim: 29 dBA;
• silent: 26 dBA.
|
| Sound power level - Cooling | 57 dBA |
| Sound power level - Heating | 57 dBA |
| Power suply | 220 - 240 Vca, monofazic, 50 Hz |
| Remote control - infrared | ARC433A87 |
|
| OUTDOOR UNIT | RX35JV |
| Dimensions (height x width x depth) | 550 x 658 x 275 mm |
| Weight | 30 Kg |
| Compressor type | Compresor oscilant inchis ermetic / Hermetically sealed swing |
| Sound power level - Cooling | 62 dBA |
| Sound power level - Heating | 62 dBA |
| Refrigerant type | R-410 |
| Additional refrigerant charge | 0,02 Kg/m - pentru lungimea tubulaturii de depaseste 10m / for piping lenght exceeding 10m |
| Operating range - Cooling (°Cdb) | -10 °C ... +46 °C
|
| Operating range - Heating (°Cwb) | -15 °C ... +20 °C
|
| Piping connection- Liquid (OD/mm) | ř 6.4 mm |
| Piping connection- Gas (OD/mm) | ř 9,52 mm |
| Piping connection- Drain (OD/mm) | ř 18 mm |
| Sound pressure level - Cooling |
• maxim: 48 dBA;
• minim: -
|
| Sound pressure level - Heating |
• maxim: 48 dBA;
• minim: -
|
| Maximum piping lenght | 15 metri |
| Maximum level difference | 12 metri |
| Power suply | 220 - 240 Vca, monofazic, 50 Hz |
|
| EQUIPMENT AND ACCESORIES INCLUDED: |
• 1 Unitate interioară FTX35JV;
• 1 Unitate exterioară RX35JV;
• 1 Telecomandă infrarosu ARC433A87;
• 2 Baterii pentru telecomandă;
• 1 Suport telecomandă;
• 1 Placa suport pentru instalarea UI;
• 2 Şuruburi pentru fixare UI;
• 2 Filtre electrostatice pt. purificarea aerului;
• 2 Filtre fotocatalitice din apatit de titan pt. dezinfectarea aerului;
• 1 Manual de Utilizare.
|
|
| DELIVERY CONDITIONS: |
Delivery time for Daikin products is between 2 hours and 7 working days, depending on existing stock from the supplier.
Delivery desired by the customer is made after full payment of the amount specified in the content of invoice.
Transport of the equipment is free of charge and provided by ATEC GLOBAL SYSTEMS.
The labor value is calculated according to the time spent and difficulty of characteristic work procedures used for equipment installation ;
Total installation cost - To the labor value is added value of materials used for installation such as: outdoor unit supports, refrigeration piping, electric cables, additional refrigerant if the route length exceeds 10 meters (wired distance between the IU and EU);
Customer may request additional fee interior works to improve the appearance of residence, to be performed simultaneously with installation of equipment.
|
|
| NOTES: |
| Energy label: scale from A (most efficient) to G (less efficient) |
| Annual energy consumption: based on average use of 500 running hours per year at full load (nominal conditions) |
| Nominal cooling capacities are based on: indoor temp. 27°Cdb, 19°Cwb; outdoor temp. 35°Cdb, 24°Cwb; equivalent piping length: 5m (horizontal) |
| Nominal heating capacities are based on: indoor temp. 20°CDB; outdoor temp. 7°Cdb, 6°Cwb; equivalent refrigerant piping: 5m |
|
| DICTIONARY |
• Ambient - - - Environment - Mediu inconjurator - Ambiental: referitor la mediul inconjurător;
• BTU - - - British Termal Unit - Unitate de masura a energiei termice exprimata prin cantitatea de căldură necesară pentru creşterea temperaturii cu 1 Grad Fahrenheit a unei cantităţi de apă de 1 Pound. 1KW/h = 3412,3 BTU/h, explicatie:
1 BTU = 1,055 KiloJoules;
1 Joule/secunda = 1 Watt, sau . . . 1 Joule = 1 Watt/secunda, deci,
1 KW/h =1000 x 3600 Watt.secs = 1000 x 3600 Joules = 3600 KiloJoules = 3600/1,055 BTU = 3412,3 BTU/h
• Cdb - - - Dry Bulb Temperature - Temperatura măsurată cu senzor uscat (cu termometru normal cu mercur);
• Cwb - - - Wet Bulb Temperature - Temperatura măsurată cu senzor umed (cu termometru al carui senzor este invelit cu o pâslă umedă de dimensiuni date);
• dBA - - - decibel A-weighting - decibel-A pondere - unitate de măsură a nivelului de zgomot ambiental;
|
|